Dibasic sodium phosphate dihydrate USP/Ph.Eur/BP PARENTEX 500G
P1611SG50046783B222GY
USP/Ph.Eur/BP PARENTEX46783B2
10028-24-7114311
Na2HPO4.2H2OJuly 2025
177.99June 2028
Sr.No.TestResultSpecificationMethod Reference
1DescriptionWhite crystals.White powder or colorless crystals.USP/Ph.Eur/BP
2SolubilityCompliesFreely soluble in water; practically insoluble in ethanol (96%)USP/Ph.Eur/BP
3Identification (By chemical test)CompliesSolution should be slightly alkalinePh.Eur/BP
4Identification (By Loss on drying)19.8%19.5% - 21.0%Ph.Eur/BP
5Identification (Sodium)CompliesA dense precipitate should form.USP/Ph.Eur/BP
6Identification (Phosphate 1)CompliesA yellow precipitate that solution in 2N nitric acid and in 6N ammonium hydroxide should form.USP
7Identification (Phosphate 2)CompliesWith ammonium molybdate solution, acidified solutions should yield a yellow precipitate which should soluble in 6N ammonium hydroxide.USP
8Identification (Phosphate 3)CompliesA yellow colour should develop.Ph.Eur/BP
9Assay (on dry basis)99.9%98.0% - 100.5%USP
10Assay (Dried substance)99.9%98.0% 101.0% (Na2HPO4)Ph.Eur/BP
11Insoluble Substances0.03%NMT 0.4%USP
12Appearance of solutionCompliesClear and colorless solution.Ph.Eur/BP
13Reducing substancesCompliesThe color of the permanganate should not completely dischargePh.Eur/BP
14Monosodium PhosphateLess than 2.5%NMT 2.5%Ph.Eur/BP
15ChloridesLess than 400 ppmNMT 400ppmPh.Eur/BP
16Sulphate (SO4)Less than 0.1%NMT 0.1%Ph.Eur/BP
17Arsenic (As)Less than 4 ppmNMT 4ppmPh.Eur/BP
18Iron(Fe)Less than 40 ppmNMT 40ppmPh.Eur/BP
19Loss on drying,130°C19.8%19.5% - 21.0%Ph.Eur/BP
20Total aerobic microbial countLess than 100 CFU/gmNMT 100 CFU/gmIn-house
21Total combined mold and yeasts countLess than 10 CFU/gmNMT 10 CFU/gmIn-house
22Bacterial endotoxin testLess than 2.5 EU/gmNMT 2.5 EU/gmIn-house
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION AS WELL AS USP, Ph.Eur, BP SPECIFICATION.
Actylis provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.