Print Certificate
Certificate
Dibasic sodium phosphate dodecahydrate USP/Ph.Eur/BP PARENTEX PLUS 5KG
I1612SR50045791B103DY
USP/Ph.Eur/BP PARENTEX PLUS45791B1
10039-32-4111644
Na2HPO4.12H2OApril 2025
358.14March 2028
Sr.No.TestResultSpecificationMethod Reference
1DescriptionColorless, transparent crystals, very efflorescentColorless, transparent crystals, very efflorescentUSP/Ph.Eur/BP
2SolubilityCompliesFreely soluble in water; practically insoluble in ethanol (96%)USP/In-house
3Identification (By chemical test)CompliesSolution should be slightly alkalinePh.Eur/BP
4Identification (By Loss on drying)60.81%57.0% -61.0%USP/Ph.Eur/BP
5Identification (Sodium)CompliesA dense precipitate should form.USP/Ph.Eur/BP
6Identification (Phosphate 1)CompliesA yellow precipitate soluble in 2N nitric acid and in 6 N ammonium hydroxide should form.USP
7Identification (Phosphate 2)CompliesWith ammonium molybdate solution, acidified solutions should yield a yellow precipitate which should soluble in 6N ammonium hydroxide.USP
8Identification (Phosphate 3)CompliesA yellow color should develop.Ph.Eur/BP
9Assay (on dried basis)98.80%98.0% - 100.5%USP
10Assay98.80%98.5% - 102.5%Ph.Eur/BP
11Insoluble Substances0.016%NMT 20mg (NMT 0.4%)USP
12Appearance of solutionCompliesClear and colorless solution.Ph.Eur/BP
13Reducing substancesCompliesThe color of the permanganate should not completely dischargePh.Eur/BP
14Monosodium PhosphateLess than 2.5%NMT 2.5%Ph.Eur/BP
15ChloridesLess than 200 ppmNMT 200ppmPh.Eur/BP
16Sulphate (SO4)Less than 500ppmNMT 500ppmPh.Eur/BP
17Arsenic (As)Less than 2ppmNMT 2ppmPh.Eur/BP
18Iron(Fe)Less than 20ppmNMT 20ppmPh.Eur/BP
19Loss on drying at 130°C60.81%57.0% -61.0%USP/Ph.Eur/BP
20Total aerobic microbial countLess than 100 CFU/gmNMT 100 CFU/gmIn House
21Total combined yeast and mould countLess than 10 CFU/gmNMT 10 CFU/ gmIn House
22Bacterial endotoxin testLess than 2.5 EU/gmNMT 2.5 EU/gmIn House
Remarks: THE CAPTIONED BATCH MATERIAL COMPLIES WITH THE PRESCRIBED QUALITY OF THE ABOVE SPECIFICATION AS WELL AS USP, Ph.Eur, BP SPECIFICATION.
Actylis provides this analytical report in good faith and to the best of its knowledge. It should not be substituted for the users own raw material quality control.
Tested By
(Chemist - Quality Control)
Approved By
(Head - Quality Control)
Computer Generated Report - Does not require Signature.
Print Certificate